Commercial Capacity Dryer Duct Booster Fan

Commercial Capacity Dryer Duct Booster Fan

4.5
(169)
Write Review
More
$ 896.50
Add to Cart
In stock
Description

Commercial Capacity Dryer Duct Booster Fan - Use this indoor mount commercial dryer duct booster for up to 4 laundromat capacity dryers (up to 1000 CFM).  This fan allows you to overcome exhaust vent design restrictions.  This dryer booster fan is a great solution to ducting commercial dryers to the outside without having to cut individual holes through each dryer. The CDB8 was designed specifically to aid the exhaust velocity of commercial capacity clothes dryers. Often times multiple clothes dryers share a common duct or a large clothes dryer exhausts into a long duct run where maintaining the transport velocity for the lint to remain suspended in the air stream is difficult. This causes lint build-up within the duct and dryer resulting in increased drying time, wasted energy and more frequent duct cleanings. The removal of the lint from the duct system can be a frequent and often times expensive task. The CDB8 is designed to boost the velocity within the duct so the lint is expelled to the outdoors or defined lint collection points. The CDB8 is designed to work on vertical and horizontal clothes dryer duct systems and can be part of a new or retrofit installation. A unique housing design with the inlet collar and outlet collar on the same plane allows the CDB8 to be used as a 90 degree elbow or with the addition of the IEK8 In-line Elbow Kit, can be installed in-line in a straight duct run. Features: Modulating exhaust reduces drying times, saving energy Maintains exhaust velocity to reduce lint build-up Single roof penetration for multiple dryers Temp activated motor cooling fan For both wall and roof terminated dryer exhaust Specifications: Motor HP: 1/2 Motor Amps: 6.2 Motor Volts: 120 8” inlet/outlet connections Dimensions: 22 1/2" Length x 15 7/8" Width, 16 1/8" Height Weight: 25.5 pounds Warranty: 1 year Download the Commercial Dryer Duct Booster CDB8 Installation Instructions Download the CDB8 Submittal Data Sheet Selecting the proper commercial Dryer Duct Booster Duct Size Dryers operate most efficiently when exhaust velocities between 1200-2200 feet-per-minute (FPM) are maintained. The number of co-ducted dryers operating, exhaust fan model selection and the diameter and length of the common exhaust duct can dramatically affect exhaust velocity. Over sizing the exhaust manifold will reduce velocities and allow more opportunity for lint to drop out of the exhaust stream. Undersized or excessively long exhaust manifolds will increase drying time and operating costs. COP controller set point adjustments will allow velocities to be fine tuned. Common exhaust manifold sizing and Dryer Booster Fan selection 1. Based on the CFM total for all connected dryers find the Total Dryer CFM value in the left column of the table equal to or greater than that CFM and determine the common manifold minimum or maximum duct diameter. 2. Trace to the right to select the Dryer Booster and determine the maximum equivalent length of common duct based upon your choice of either the minimum or maximum duct diameter. Example: 4 Dryers @ 225 CFM/ea 4 x 225 = 900 Total Dryer CFM Minimum duct diameter at 900 CFM is 9 inches Maximum duct diameter at 900 CFM is 12 inches Installing a common duct sized between 9” and 12” is the optimal size range for maintaining a proper velocity across all operating conditions. Trace to the right to select the Dryer Booster and maximum equivalent feet of common duct based on your duct diameter choice.   Please note - This item is subject to a 25% restocking fee if you want to return it.

Dryer Booster Fans

COP2DB Pressure Control

Dryer Duct Booster Fan - Meets UL 705

Ge Appliances GTX52EASPWB Front Load Electric Dryer

The Auto-Draft can be installed on any wood or coal burning stove pipe 5 to 8 in diameter. It is designed to solve draft problems without increasing the height or diameter of the chimney. With the Auto-Draft your hard starting stove draws immediately. No smoky back up--even with moist or hard to ignite types of wood. Once the fire is burning adjust the variable speed control knob on the electrical box to achieve the maximum efficiency of your stove.

Tjernlund AD1 Draft Inducer for Wood

Fresh Air Intake Kit with Booster Fan and Intake Hood Today's building construction techniques minimize fresh air intake into buildings. This fresh air intake fan is a simple, affordable way to bring in fresh outside air in order to dilute trapped pollutants and replace air vented out by exhaust fans and fuel burning equipment. It is easily installed and does not have to be hardwired because it comes with a plug. You can use an on off switch or timer to operate this fan.

Tjernlund Fai4 Fresh Air Intake Fan with Hood

Dryer Booster Fans

Duct Airstat

Quiet, powerful, compact; the most user-friendly fan in the industry In-line construction to reduce lint build-up Exclusive mounting brackets included

Continental Fan Dryer Booster Kit w/Mounted Pressure Switch - 150 cfm